| CHP unit Typ | Generator-power [KW] |
Thermal Power [KW] |
Elektric efficiency [%] |
Intercooler- temperature [°K] |
Cylinder number/ Arrangement |
Weight approx. [t] |
Dimensions L x B x H [m] |
|---|---|---|---|---|---|---|---|
|
Heat recovery: Heating water temperature: 90 °C outlet flow, max 70 °C return flow Special layout for up to 120 °C outlet flow temperature available on request Rating Conditions: Combustion air/Ambient temperature 27 °C; Altitude max. 300 m; Methan concentration 5% Exhaust gas emissions: NOx < 500 mg/Nm³ / CO < 1000 mg/Nm³ |
|||||||
|
Naturally aspirated lean-burn engine
|
FMB-43-BSK | 34 | 57 | 32 | - | 4 / Reihe | 2.2 | 2.8 x 0.85 x 1.85 |
| FMB-65-BSK | 53 | 82 | 32.3 | - | 6 / Reihe | 2.3 | 2.8 x 0.85 x 1.85 |
| FBM-100-BSK | 81 | 135 | 31.6 | - | 6 / Reihe | 3.2 | 3.6 x 1.05 x 2.05 |
| FMB-125-BSK | 101 | 164 | 32.6 | - | 8 / V 90° | 3.4 | 3.6 x 1.25 x 2.05 |
| Turbo engine | |||||||
| FMB-130-BSM | 105 | 123 | 36.7 | 40 | 6 / Reihe | 3.5 | 3.6 x 1.25 x 2.09 |
| FMB-200-BSM | 160 | 223 | 35.5 | 80 | 6 / Reihe | 3.5 | 3.6 x 1.25 x 2.45 |
| FMB-230-BSM | 185 | 215 | 36.7 | 50 | 6 / Reihe | 3.5 | 3.6 x 1.25 x 2.45 |
| FMB-255-BSM | 200 | 273 | 35.2 | 80 | 8 / V 90° | 4.3 | 3.6 x 1.45 x 2.45 |
| FMB-285-BSM | 233 | 262 | 36.9 | 50 | 8 / V 90° | 4.3 | 3.6 x 1.45 x 2.45 |
| FMB-375-BSM | 300 | 439 | 35.7 | 80 | 12 / V 90° | 5.4 | 4.0 x 1.45 x 2.45 |
| FMB-430-BSM | 350 | 371 | 38.1 | 50 | 12 / V 90° | 5.4 | 4.0 x 2.2 x 3.0 |
| FMB-750-BSM | 609 | 652 | 39.5 | 55 | 12 / V 90° | 11.6 | 5.1 x 2.2 x 3.0 |
| FMB-1000-BSM | 810 | 867 | 39.3 | 55 | 16 / V 60° | 13.5 | 5.7 x 2.2 x 3.0 |
| FMB-1180-BSM | 958 | 1007 | 39.5 | 55 | 16 / V 60° | 14.8 | 5.7 x 2.2 x 3.0 |
| FMB-2000-BSM | 1572 | 1758 | 37.8 | 50 | 16 / V 60° | 16.5 | Auf Anfrage |
| FMB-2200-BSM | 1750 | 1841 | 37.9 | 50 | 18 / V 60° | 29 | Auf Anfrage |