| CHP unit Type | Generator power [KW] |
Thermal power [KW] |
Elektric efficiency [%] |
Intercooler- temperature [°K] |
Cylinder number/ Arrangement |
Weight approx. [t] |
Dimensions L x B x H [m] |
|---|---|---|---|---|---|---|---|
|
Heat recovery: Heating water temperature: 90 °C outlet flow, max 70 °C return flow Special layout for up to 120 °C outlet flow temperature available on request Rating Conditions: Combustion air/Ambient temperature >+5°C / <+27°C; Altitude max. 300 m; Methan concentration 5% Exhaust gas emissions: NOx < 500 mg/Nm³ / CO < 1000 mg/Nm³ |
|||||||
| Naturally aspirated lean-burn engine | |||||||
| FMB-100-BSM | 81 | 128 | 32.6 | - | 6 / Reihe | 3.2 | 3.6 x 1.05 x 2.05 |
| FMB-125-BSM | 101 | 158 | 33.8 | - | 8 / V 90° | 3.4 | 3.6 x 1.25 x 2.05 |
| Lean burn turbocharged engine | |||||||
| FMB-200-BSM | 160 | 221 | 36.3 | 80 | 6 / Reihe | 3.5 | 3.6 x 1.25 x 2.45 |
| FMB-230-BSM | 185 | 207 | 37.9 | 50 | 6 / Reihe | 4.3 | 3.6 x 1.25 x 2.45 |
| FMB-255-BSM | 200 | 264 | 36.4 | 70 | 8 / V 90° | 4.3 | 3.6 x 1.45 x 2.45 |
| FMB-285-BSM | 233 | 253 | 38.1 | 50 | 8 / V 90° | 4.3 | 3.6 x 1.45 x 2.45 |
| FMB-320-BSM | 260 | 289 | 40.8 | 50 | 12 / V 90° | 4.3 | 3.6 x 1.45 x 2.45 |
| FMB-375-BSM | 300 | 403 | 36.9 | 80 | 12 / V 90° | 5.4 | 4.0 x 1.45 x 2.45 |
| FMB-430-BSM | 350 | 365 | 38.9 | 50 | 12 / V 90° | 5.4 | 4.0 x 1.45 x 2.45 |
| FMB-500-BSM | 400 | 456 | 40.2 | 50 | 12 / V 90° | 5.5 | 4.0 x 1.45 x 2.45 |