Natural gas cogen 60 Hz LowNOx

Reduce energy costs  -  avoid CO2 -  save resources

SCHMITT ENERTEC GmbH - Siemensstraße -  56743 Mendig  - Germany
Phone +49 2652/93518 10 - Fax. +49 2652/93518 22
  change to SI-scales                                                                                              Download sheet as PDF
 Type Generator-Power
[KW]
Thermal
Power
[BTU/hr]
Electric
Efficiency
[%]
Intercooler-
Temperature
[°F]
Cylinder Number/
Arrangement
Weight
approx.
[lbs]
Dimensions
L x W x H
[inch]

Heat extraction:
Heating water temperature: 194 °F outlet flow temp., max 158 °F return flow temp.
Special layout up to 248 °F outlet flow temperature upon request
Rating Conditions:
Combustion air/ambient temperature 81 °F; Altitude max. 1000 ft;  Methan number > 76:
Exhaust gas emissions:
 NOx < 50 ppm ; 0,15 Gms/ Bhp -hr
 NOx < 1100 ppm; 0,6 Gms/ Bhp -hr  

 

All Data on this sheet is for information only  and not binding. Guaranteed are only the values in commercial 
 

Rich burn, naturally aspirated
FMB-62- GSK 62 300,148 34,1 - 4 / inline 5,300 110 x 33 x 73
FMB-80-GSK 80 423,127 34,3 - 6 / inline 5,800 110 x 33 x 73
MB-110- GSK 110 654,903 32,8 - 6 / inline 6,800 141 x 41 x 81
MB-135-GSK 135 795,822 33,3 - 6 / inline 7,000 141 x 41 x 81
MB-160-GSK 160 934,830 33,4 - 8 / V 90° 7,500 141 x 49 x 81
MB-240-GSK 240 1,443,412 33,4 - 12 / V 90° 9,550 141 x 49 x 81
Rich burn, turbocharged with emission gas return
FMB-215-GSM 195 1,074,700 34,3 50 6 / inline 8,500 141 x 49 x 81
FMB-230-GSMK 266 1,396,773 35,1 50 8 / V 90° 9,500 141 x 49 x 81
FMB-270-GSMK 370 2,129,107 35,1 50 8 / V 90° 13,300 141 x 49 x 81