ENERGIN® GEN+

Generator Sets with heat recovery

ENERGIN® GEN+

Our ENERGIN® GEN+ units are generators sets with heat recovery from engine jacket water, lube oil and first stage mixture cooling. For more efficient heat recovery please refer to our CHP units. ENERGIN® GEN+ units are prepared for power production in island or parallel mode with other generators and/or the utility.

Basic features are:

  • Electric power range 115 – 500 kW
  • Thermal power range 98 – 376 kW
  • Up to 42,7 % electric efficiency
  •  Up to 70,2 % overall efficiency
  • Low noise option <70 dB(A)
  • Plug and play type
  • Fuel options: Natural gas, Biogas, Wood gas, LPG

        RSE_Download_05   Download Flyer: ENERGIN® GEN+ | 50 Hz

        RSE_Download_05   Download Flyer: ENERGIN® GEN+ | 60 Hz

50 Hz

Natural gas, 400 V, 50 Hz                      Download data sheets

ENERGIN® typeEngine typeElectrical power / kWElectrical efficiency / %Thermal power / kWOverall efficiency / %
M06 GEN+ G140M06-GT0D4114038,611169,2
M06 GEN+ G200M06-GTID4120041,013167,8
M06 GEN+ G250M06-GT2D4125041,812863,2
M08 GEN+ G260M08-GTID4126041,017368,3
M08 GEN+ G333M08-GT2D4133341,917463,8
M12 GEN+ G400M12-GTID4140041,126468,2
M12 GEN+ G500M12-GT2D4150042,125563,6

Biogas, 400 V, 50 Hz                               Download data sheets

ENERGIN® typeEngine typeElectrical power / kWElectrical efficiency / %Thermal power / kWOverall efficiency / %
M06 GEN+ B140M06-BT0D4114039,39866,8
M06 GEN+ B200M06-BTID4120041,812066,9
M06 GEN+ B250M06-BT2D4125042,612063,0
M08 GEN+ B260M08-BTID4126041,715967,2
M08 GEN+ B333M08-BT2D4133342,616263,3
M12 GEN+ B400M12-BTID4140041,924167,1
M12 GEN+ B500M12-BT2D4150042,724163,3

LPG, 400 V, 50 Hz                                   Download data sheets

ENERGIN® typeEngine typeElectrical power / kWElectrical efficiency / %Thermal power / kWOverall efficiency / %
M06 GEN+ P115M06-PT0D4111530,714870,2
M06 GEN+ P173M06-PTID4117334,917169,4
M06 GEN+ P205M06-PT2D4120535,817466,2
M08 GEN+ P233M08-PTID4123335,023370,0
M08 GEN+ P260M08-pT2D4126035,922466,8
M12 GEN+ P350M12-PTID4135035,134870,0
M12 GEN+ P450M12-PT2D4145036,037666,1

Woodgas, 400 V, 50 Hz                        Download data sheets

ENERGIN® typeEngine typeElectrical power / kWElectrical efficiency / %Thermal power / kWOverall efficiency / %
M06 GEN+ H122M06-HT2D4112234,810263,9
M08 GEN+ H166M08-HT2D4116634,914064,3
M12 GEN+ H250M12-HT2D4125035,020864,1

 

60 Hz

Natural gas, 480V, 60 Hz

ENERGIN® typeEngine typeElectrical power / kWElectrical efficiency / %Thermal power / kWOverall efficiency / %
GEN+ G150/60HzM06-GT0D4115037,012768,4
GEN+ G210/60HzM06-GTID4121039,514967,5
GEN+ G250/60HzM06-GT2D4125040,314563,7
GEN+ G280/60HzM08-GTID4128039,520067,7
GEN+ G333/60HzM08-GT2D4133340,419463,9
GEN+ G420/60HzM12-GTID4142039,630067,9
GEN+ G500/60HzM12-GT2D4150040,528563,6

Biogas, 480 V, 60 Hz

ENERGIN® typeEngine typeElectrical power / kWElectrical efficiency / %Thermal power / kWOverall efficiency / %
GEN+ B150/60HzM06-BT0D4115037,811266,0
GEN+ B210/60HzM06-BTID4121040,213465,9
GEN+ B250/60HzM06-BT2D4125041,113062,5
GEN+ B280/60HzM08-BTID4128040,218066,1
GEN+ B333/60HzM08-BT2D4133341,217562,8
GEN+ B420/60HzM12-BTID4142040,427066,4
GEN+ B500/60HzM12-BT2D4150041,225862,5

LPG, 480 V, 60 Hz

ENERGIN® typeEngine typeElectrical power / kWElectrical efficiency / %Thermal power / kWOverall efficiency / %
GEN+ P130/60HzM06-PT0D4113031,016169,4
GEN+ P173/60HzM06-PTID4117333,518469,1
GEN+ P205/60HzM06-PT2D4120534,318965,9
GEN+ P233/60HzM08-PTID4123333,524869,1
GEN+ P260/60HzM08-PT2D4126034,324166,1
GEN+ P350/60HzM12-PTID4135033,637469,5
GEN+ P450/60HzM12-PT2D4145034,540765,7

Woodgas, 60 Hz

ENERGIN® typeEngine typeElectrical power / kWElectrical efficiency / %Thermal power / kWOverall efficiency / %
GEN+ H140/60HzM06-HT2D4114033,312563,0
GEN+ H180/60HzM08-HT2D4118033,416063,1
GEN+ H275/60HzM12-HT2D4127533,524963,8